महाराष्ट्र अभियंता सेवा (विद्युत व यांत्रिकी) मुख्य परीक्षा २०२२ पेपर १

महाराष्ट्र अभियंता सेवा (विद्युत व यांत्रिकी) मुख्य परीक्षा २०२२ पेपर १ Questions And Answers:

आपल्या मित्रांना पाठवा :
MahaNMK PRO · लाइव्ह परीक्षा

हीच प्रश्नपत्रिका लाइव्ह परीक्षा म्हणून द्या Experience this paper as a live exam

  • दर वेळी नवीन क्रम — questions shuffled every attempt, so you test yourself, not your memory
  • खरा काउंटडाउन — a server-side timer, auto-submit at 00:00, just like the exam hall
  • लगेच निकाल — score, percentile and answer-wise review the moment you submit
Live Exam PRO सदस्यांसाठी अमर्यादित · Unlimited for PRO members
1.
A resistance of 30 Ω is connected across a 240 V supply. If a resistance of R ohm is connected in parallel with a 30 ohm resistor across the same supply, the current drawn becomes triple of original one. The value of unknown resistance R is

2.
Joules/second is also called as

3.
KCL and KVL are applicable for

4.
In an R-L-C series AC circuit the value of XL and XC are equal the circuit current becomes

5.
_____________ of an a.c. circuit is the reciprocal of its impedance.

6.
Under steady state condition, capacitor acts as an/a _________ and inductor as an/a _____________.

7.
A resultant current is made of two components. A 10 A DC component and a sinusoidal component of maximum value 14.14 A. The average value of the resultant current is

8.
The ratio of maximum value to the r.m.s. value of an alternating quantity is known as

9.
In the given circuit the current flowing through the 8 Ω resistor is
आकृती

10.
In DC network ideal current source has internal resistance of

11.
A series magnetic circuit having the combination of iron ring with an air gap. The total mmf is

12.
A short circuit coil of 100 turns surrounds the middle of a bar magnet.
If the magnet sets up a flux of 60 microwb, the average value of emf induced in the coil when the magnet is taken far away from the coil in 0.04 sec. is

13.
✖ रद्द प्रश्न · Cancelled Ideal transformer have the features of

14.
If primary winding of single phase transformer is connected to d.c. supply, it results in

15.
The Δ-Y winding connection of three phase transformer is commonly used for

16.
A capacitor with a capacitance of 500 pF is charged to 100 V. The plates of the capacitor are then separated till capacitance reduces to 100 pF. Calculate change in potential across the capacitor.

17.
Scott connection of three phase transformer is used for

18.
A transformer takes a current of 0.6 A and absorbs 64 W when the primary is connected to its normal supply of 200 V, 50 Hz; the secondary being on open circuit. The iron loss current is

19.
A transformer has full-load copper loss of 400 W. The copper loss at half full-load will be

20.
In short circuit test of transformer, the transformer is loaded with

अधिक प्रश्न पुढील पेजवर:

महाराष्ट्र अभियंता सेवा (विद्युत व यांत्रिकी) मुख्य परीक्षा २०२२ पेपर १ Question And Answers

आता मिळवा सर्व जाहिराती Telegram Channel वर (अगदी मोफत) - येथे क्लिक करा

Maha NMK Here You will get the list of all district from Maharashtra. You Can Select Any Disctrict From The List And Get Latest Recruitment News For The District. Keep Visiting MahaNMK Daily For The Latest Recruitment new and Free Job Alert

Whatsapp Group

© Maha NMK® | Copyright 2015 - 2026 All Rights Reserved.

Made with ❤ in India.